Skip to main content
Version: 5.0.x {stable}

PWM capture

RC input or PWM input configuration.

info
  • RC input - only one channel on one input. Multiple channels, sbus, ..., are not supported.
  • If you do not see these variables in your FW. PWM capture is disabled in your FW
  • Input duty cycle range is from 10[us] - 10 000[us]
  • Reading resolution is approx +-10[us]
info

All here listed variables are located in folder /common.


States

pwm_ch1 [us]

pwm_ch2 [us]

Input readings of pwm inputs. If pwm is not present, last value is shown. Checking for loosed signal is done in PWM Signal Conditioner. This is just reading the input.

Pwm chanel is not coresponding to pin names. Check device HW manual or read state description.

info

Example, AX controller, state description:
-> pwm_ch1 uint16 : [us] raw pwm signal on DIN4
pwm_ch1 input is present on DIN4 on AX controller.

tip

If you see wrong values, try to invert the reading of the signal using the ppmconf


Parameters

ppmconf

pwm capture input configuration

ValueDescription
0default
255inverted signal